Your Current Location > Home > Products > Gas Discharge Tubes

Φ30x28.5mm - H2R30-800xx

AC Power line N-PE applications

Class I and Class II Surge protection

Voltage : 800V

Up: 1500V

Uc:  255V

In:  100KA 

Iimp: 30KA

Imax: 200KA


Specification of  H2R30-800xx

Dc spark-over voltage (100V/s)      1)

800V ±20%

Maximum impulse spark-over voltage @ 1KV/μs

1500V

Breakdown time   

           - typical values

100ns

20ns

Insulation resistance @DC250V

  1000MΩ

Class I  according to IEC 61643-11

Max continuous operating voltage at 50/60 Hz           Uc

Nominal discharge current 8/20μs                               In

Impulse current 10/350μs                                             Iimp

 

255V

100KA

30KA

Class II  according to IEC 61643-11

Max continuous operating voltage at 50/60 Hz           Uc

Nominal discharge current 8/20μs                               In

Maximum discharge current 8/20μs                            Imax

 

255V

100KA

200KA

capacitance at 1MHz

8pF

Weight

~ 74g

UL 1449 Certification

On the UL List


 ul.png

Delivery time

20days

Operation and storage temperature

-40 … +90

Marking, Blue

1) At delivery AQL 0.65 level II Military Standard 105E.

    Approvals/ Standards   IEC61643-11

2R800 YY

800 - Nominal voltage

YY - Year of production