Tel:+86-755-27465585
Fax:+86-755-27270662
Email:sales@huaandz.com
Website:www.huaandz.com
Add:5F,Building C,No.30,Aviation Road,SanWei,XiXiang Street,BaoAn District,ShenZhen,China
Your Current Location >Home > Products > Gas Discharge Tubes > Φ16x4.5mm - H2R16-600
Φ16x4.5mm - H2R16-600

Φ16x4.5mm - H2R16-600

AC Power line N-PE applications

Class I and Class II Surge protection

Voltage : 600V

Up: <1500V

Uc:  255V

In:  30KA 

Iimp: 12KA

Imax: 60KA

If:  100A

TOV: 300A


Specification of  H2R16-600

Dc spark-over voltage (100V/s)      1)

600±20%

Front of wave spark-over voltage at 1.2/50us, 6KV

1500V

Breakdown time   

           - typical values

100ns

20ns

Insulation resistance @DC250V

  10000MΩ

Class I  according to IEC 61643-11

Max continuous operating voltage at 50/60 Hz           Uc

Nominal discharge current 8/20μ                              In

Impulse current 10/350μ                                            Iimp

Follow Current at 50/60Hz at 255V                               If

 

255V

30KA

12KA

100A

Class II  according to IEC 61643-11

Max continuous operating voltage at 50/60 Hz           Uc

Nominal discharge current 8/20μ                              In

Maximum discharge current 8/20μ                            Imax

Follow Current at 50/60Hz at 255V                                If

 

255V

30KA

60KA

100A

AC discharge current (TOV at 1200V ,1 operation 50Hz,0.2 s)

300A

capacitance at 1MHz

6pF

Weight

4g

UL 1449 Certification

On the UL List


 ul.png

Delivery time

20days

Operation and storage temperature

-40 … +90

Marking, Blue 1) At delivery AQL 0.65 level II Military Standard 105E.

2) In ionized mode

3) DC Sparkover may exceed +/-30% ,but will continue to protect without venting

Test according to ITU-T Rec. K.12

2R600 YY

600 - Nominal voltage

YY - Year of production